Thermostat with OT communication

PT52 Order number: 657

PT52 Intelligent Thermostat with OpenTherm (OT +) communication.

1 682 Kč 1 390 Kč without VAT 1,68 bez DPH (RP není součástí ceny)
pc

Description of product

Properties PT52:

Room thermostat for controlling heat sources with OpenTherm (OT +) communication (= data communication system between boiler and thermostat).

Advantages PT52:

  • large BACKLIGHT display and simple operation
  • intuitive navigation of settings in selected language (CZ / PL / EN / DE / RU / SVK)
  • 9 weekly programs for CH (with six temperature changes per day)
  • 1 week program for DHW (with 3 time intervals per day)
  • equitherm regulation
  • equitherm regulation with internal temperature correction
  • building influence constant
  • PI regulation
  • premature start of heating (PSH) with advance setting
  • choice of boiler type (eg Thermon, Dakon, Quantum, Geminox, Ferroli, Viessmann and others)
  • fast change of required temperature CH and DHW
  • holiday mode
  • summer mode
  • current temperature correction
  • key lock
  • aut. change to summer / winter time
  • displaying the information sent by the boiler via the OT line (actual CH
  • emperature, calculated CH temperature, power in%, flow, return temperature and outdoor temperature)
  • operating hours for both CH and DHW
  • frost protection
  • back-up for about 8 hours

 

PT52 can be used for boilers communicating according to the OpenTherm protocol and meeting the given technical specifications.

Technical specification

Power supply universal directly over the line OT
Thermostat type wire with OT communication
Type of control OTC/PI control
Accuracy 0,5 °C
Dimensions (LxWxD) 136,5x83x28,5 mm
Protection IP20
Working temperature 0 °C to 40 °C
Switching element -
Output OpenTherm
Temperature changes per day 6
Range of adjustable temperature 5 °C to 85 °C
Temperature setting by 0, 5 °C
Min. programming time 10 min
Min. indication step 0, 1 °C
Communication type two-way OpenTherm (pair max.50 m, without polarity)
Min. Programming time for DHW 60 min
Temp. setting range of DHW 0 °C to 65 °C
DHW hysteresis 5, 0 °C