Electronic unit designed to control up to four independent hot water heating circuits. Based on the requests from the thermostats in each room, it switches on the given thermoelectric drive, boiler and circulation pump.
When there is a request for heating from the connected thermostats at the input (max. 4), the thermovalve opens for the given circuit and after one minute the circulation pump and boiler are switched on. The pump and boiler are switched off if none of the connected thermostats require heating.
It is also possible to connect an external control to the unit to switch off all circuits (it is possible to use a switching clock to save energy during heating in the absence of people).
Power supply | 230 V AC/ 50Hz |
---|---|
Consumption | 2, 0 VA (standby < 0.2 W) |
Number of inputs | 4 |
Number of outputs | 4 (Imax=6A) |
Switching element | triac max. 0.2A/ 2xSEH01-NC |
Pump outputs | relé, max.10A |
Boiler outputs | relé, max.10A |
Protection | IP20 |
Working temperature | 0 °C to 40 °C |