When there is a request for heating from the connected wired thermostats at the input (max. 8 zones), the thermovalve for the given zone opens and after the set delay, the output for the circulation pump and the voltage-free output for boiler control are switched on. The pump and boiler are switched off if none of the connected thermostats request heating.
Power supply | 230 V AC/ 50Hz |
---|---|
Consumption | 2, 0 VA (standby < 0.2 W) |
Number of inputs | 8 |
Number of outputs | 8 (Imax=5A) |
Switching element | relay |
Pump outputs | relay , max.5A |
Boiler outputs | relay , max.5A |
Protection | IP20 |
Working temperature | -20 °C to 60 °C |